Tz-6106 Built-in cm horizontal waterproof and oil-proof limit switch

TZ-6106  Water-proof and Oil-proof Built-in CM Horizontal Limit SwitchFeaturesBuilt-in CM horizontal limit switchHigh mechanical strength, mainly consists of aluminum castWater-proof and oil-proof constructionSame rated value and characteristic with CM horizontal limit switchVarious actuators for different applications 

Featured Products

TZ-6106  Water-proof and Oil-proof Built-in CM Horizontal Limit Switch

Features

Built-in CM horizontal limit switch

High mechanical strength, mainly consists of aluminum cast

Water-proof and oil-proof construction

Same rated value and characteristic with CM horizontal limit switch

Various actuators for different applications

 

 

Ratings

 

 

Rated Voltage

Noninductive Load (A)

Inductive Load (A)

Resistance Load

Lamp Load

Inductive Load

Motor Load

NC

NO

NC

NO

NC

NO

NC

NO

125VAC

5

5

1.5

0.7

3

3

2

1

250VAC

5

5

1

0.5

3

3

1.5

0.8

8VDC

5

5

3

3

5

4

3

3

14VDC

5

5

3

3

4

4

3

3

30VDC

5

5

3

3

4

4

3

3

125VDC

0.4

0.4

 

 

 

 

 

 

250VDC

0.2

0.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Inrush Current

 

 

N.C: below 24A,

N O: below 12A

 

 

NOTES: Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec. max.(DC).

2. Lamp load has an inrush current of 10 times the steady-state current while motor load has an inrush current of 6 times the steady-state current

3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.

 

 

Characteristics

 

 

Operation speed

5mm-0.5m/s

Operating frequency

Electrical: 20 operations/min

Contact resistance

25m Ω max. (initial value)

Insulation resistance

100mΩmin. (below 500VDC)

Dielectric strength

1500V^C, 50/60 Hz for 1 minute between current-carrying and non -current-carrying metal parts

1500V^C, 50/60 Hz for 1 minute between current-carrying and non -current-carrying metal parts

1500V^C, 50/60 Hz for 1 minute between each terminal and ground

Vibration

10-55Hz, 1.5mm double amplitude

Shock

Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30GS)

Ambient temperature

Using: -20-+80ºC (With no icing)

Humidity

<95% RH

Electrical life

500,000 operations above

Protection level

IP66

 NOTES: The default size of conduit connector is M20x1.5, outfiting cable connector. Conduit connector size is PG13.5, with product model nurrber plus (-P), example:TZ-6104-P.

 

 

 

Operating Characteristics

 

Model

TZ-6

TZ-6001

TZ-6002 | TZ-6003

TZ-6004

TZ-6043

TZ-6101

TZ-6102|TZ-6103

TZ-6104

TZ-6143

Operating force

OF(Max.)

250~350g

250~350g

570g

570g

800g

500g

640g

640g

Release force

RF(Min.)

114g

114g

170g

170g

240g

100g

230g

230g

Pre-travel

PT(Max.)

0.4mm

0.5mm

4mm

4mm

2mm

1mm

5mm

5mm

Movement differential

MD(Max.)

0.05mm

0.05mm

0.4mm

0.4mm

0.1mm

0.12mm

0.4mm

0.4mm

Over travel

OT(Min.)

5.5mm

3.6mm

6mm

6mm

5mm

3.5mm

6mm

6mm

Operating Position

OP(mm)

38.2 ± 0.8mm

49.7 ± 1mm

 

 

45.8 ± 0.8mm

49.7 ± 0.8mm

 

 

Contact us